Single Slope Buildings
Single-Sloped Roof
Single Slope Building
Type S
Roof Design
Each "Type S" building shall have a single sloped (shed) roof with a pitch of 1 1/2"over the building width. The 16" wide interlocking roof panels shall vary from a nominal 24 to 18 gauge depending upon the loading conditions. They shall be attached to the wall cap through factory punched holes with #14 corrosion resistant fasteners.
The roof system shall include a gutter and a 2" X 3" downspout system at low sidewall, matching eave trim high side, and matching rake trim at the building endwalls. All gutters and trim shall be nominal 26 gauge galvanized steel pre-painted Arctic White or Roman Bronze.
Wall Design
The roof system is supported by a fluted, nominal 24 gauge, embossed, factory painted, 16" wide X 3" deep interlocking wall panel. The panels are fastened at the top and bottom to galvanized structural channels and wall caps with 3/8" diameter electrogalvanized machine bolts, through factory punched holes.
Structural Framing
Transmission of horizontal wind loads across the building shall be made through the roof panel system and no separate roof or wall diagonal bracing shall be required.
Where required for proper transmission of lateral wind loads, structural frame wind bents shall be installed. Wind bents shall consist of a prime painted column and rafter bolted assembly of steel conforming to ASTM A 36 specifications.
View Single Slope Building Technical Specifications
View Accessories
Wall
Interior Wall
Interior Roof
Exterior Roof
Single Slope Building Specification Drawings - General specifications for the product.
Single Slope Building Approval Drawings -Drawings sent to the customer to verify design and dimensions; also to verify the sales contract description of what we agreed to supply.
Single Slope Building Erection/Final Drawings -Drawings showing floor plan, base channel with anchor bolt locations, elevations and roof plan used with details and installation instruction for building construction.
|